The brighter-fatter effect in the JWST MIRI Si:As IBC detectors I. Observations, impact on science, and modeling
Author
Argyriou, I.Lage, C.
Rieke, G.H.
Gasman, D.
Bouwman, J.
Morrison, J.
Libralato, M.
Dicken, D.
Brandl, B.R.
Álvarez-Márquez, J.
Labiano, A.
Regan, M.
Ressler, M.E.
Affiliation
Steward Observatory and the Department of Astronomy, The University of ArizonaIssue Date
2023-12-15
Metadata
Show full item recordPublisher
EDP SciencesCitation
A&A, 680, A96 (2023)Journal
Astronomy and AstrophysicsRights
© The Authors 2023. Open Access article, published by EDP Sciences, under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0).Collection Information
This item from the UA Faculty Publications collection is made available by the University of Arizona with support from the University of Arizona Libraries. If you have questions, please contact us at repository@u.library.arizona.edu.Abstract
Context. The Mid-Infrared Instrument (MIRI) on board the James Webb Space Telescope (JWST) uses three Si:As impurity band conduction (IBC) detector arrays. The output voltage level of each MIRI detector pixel is digitally recorded by sampling up the ramp. For uniform or low-contrast illumination, the pixel ramps become nonlinear in a predictable way, but in areas of high contrast, the nonlinearity curve becomes much more complex. The origin of the effect is poorly understood and currently not calibrated out of the data. Aims. We provide observational evidence of the brighter-fatter effect (BFE) in MIRI conventional and high-contrast coronagraphic imaging, low-resolution spectroscopy, and medium-resolution spectroscopy data, and we investigate the physical mechanism that gives rise to the effect on the MIRI detector pixel raw voltage integration ramps. Methods. We used public data from the JWST/MIRI commissioning and Cycle 1 phase. We also developed a numerical electrostatic model of the MIRI detectors using a modified version of the public Poisson_CCD code. Results. We find that the physical mechanism behind the BFE manifesting in MIRI data is fundamentally different to that of chargecoupled devices and photodiode arrays such as the Hawaii-XRG near-infrared detectors used by the NIRISS, NIRCam, and NIRSpec instruments on board JWST. Observationally, the BFE makes the JWST MIRI data yield 10-25% larger point sources and spectral line profiles as a function of the relative level of de-biasing of neighboring detector pixels. This broadening impacts the MIRI absolute flux calibration, time-series observations of faint companions, and point spread function modeling and subtraction. We also find that the intra-pixel 2D profile of the shrinking Si:As IBC detector depletion region directly impacts the accuracy of the pixel ramp nonlinearity calibration model. © The Authors 2023.Note
Open access journalISSN
0004-6361Version
Final Published Versionae974a485f413a2113503eed53cd6c53
10.1051/0004-6361/202346490
Scopus Count
Collections
Except where otherwise noted, this item's license is described as © The Authors 2023. Open Access article, published by EDP Sciences, under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0).

