dc.identifier.citationWang, M., Pau, A., Zhang, G. et al. Monitoring prestress in plates by sideband peak count-index (SPC-I) and nonlinear higher harmonics techniques. Nonlinear Dyn 111, 15749–15766 (2023). https://doi.org/10.1007/s11071-023-08747-6
dc.identifier.issn0924-090X
dc.identifier.doi10.1007/s11071-023-08747-6
dc.identifier.urihttp://hdl.handle.net/10150/674017
dc.description.abstractPropagating guided waves in a homogeneous, isotropic, prestressed, hyperelastic plate show nonlinear characteristics that depend on the state of initial prestress. These nonlinear phenomena include higher harmonic generation, occurring when Lamb wave modes of different frequencies (ωa and ωb) are allowed to mix within the material generating secondary waves at frequencies 2ωa,2ωbandωa±ωb . Further, if prescribed internal-resonance conditions are satisfied, the amplitude of secondary waves increases in space, providing a response quantity which is dependent on prestress and easy to be observed. Using the finite element method, in this paper we investigate the time and space evolution of higher harmonics arising in one-way wave mixing. The influence of prestress on the response is elucidated, observing the nonlinear parameter β . It is further shown that the nonlinear ultrasonic technique called sideband peak count-index (SPC-I) can provide an effective monitoring tool for prestress. © 2023, The Author(s).
dc.language.isoen
dc.publisherSpringer Science and Business Media B.V.
dc.rights© The Author(s) 2023. This article is licensed under a Creative Commons Attribution 4.0 International License.
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.subjectInitial stress
dc.subjectInternal resonance
dc.subjectNonlinear ultrasounds
dc.subjectSideband peak count-index technique
dc.subjectWave-mixing
dc.titleMonitoring prestress in plates by sideband peak count-index (SPC-I) and nonlinear higher harmonics techniques
dc.typeArticle
dc.typetext
dc.contributor.departmentDepartment of Civil and Architectural Engineering and Mechanics, University of Arizona
dc.identifier.journalNonlinear Dynamics
dc.description.noteOpen access article
dc.description.collectioninformationThis item from the UA Faculty Publications collection is made available by the University of Arizona with support from the University of Arizona Libraries. If you have questions, please contact us at repository@u.library.arizona.edu.
dc.eprint.versionFinal Published Version
dc.source.journaltitleNonlinear Dynamics
refterms.dateFOA2024-08-09T00:15:20Z


Files in this item

Thumbnail
Name:
s11071-023-08747-6.pdf
Size:
3.350Mb
Format:
PDF
Description:
Final Published Version

This item appears in the following Collection(s)

Show simple item record

© The Author(s) 2023. This article is licensed under a Creative Commons Attribution 4.0 International License.
Except where otherwise noted, this item's license is described as © The Author(s) 2023. This article is licensed under a Creative Commons Attribution 4.0 International License.